메뉴바로가기 본문바로가기
  • 제품
  • BGMS
  • GDH enzyme BGM
BGMS

STANDARD GlucoNavii Pro

It can measure blood glucose through venous, capillary, arterial blood and as well as neonatal blood using GDH-FAD enzyme.. Its Easy Light™ function helps the user check the glucose level through the LED light and the ejector allows an easier removal of the strip.

썸네일1
썸네일1
  • ce
Advantage
  • GDH-FAD enzyme (Capillary, Venous, Arterial and Neonatal blood available)
  • No coding
  • Fasting, Pre & Post Meal Mark
  • Wide Hematocrit Range (0~70%)
  • Strip Ejection Function
  • Easy Light™ (Glucose level indicaitor)
  • Specification
    • Enzyme

      Glucose Dehydregenase-FAD biosensor

    • Measurement Range

      10 - 600mg/dL (0.6 - 33.3 mmol/L)

    • Test Time

      5 sec

    • Sample Volume

      0.5 µl

    • Hematocrit

      0 - 70%

    • Unit

      mg/dL

    • Memory

      Up to 1,000 tests

    • Battery

      3V battery (CR2032)

  • Interpretation of results
    주문정보의 cat. no., 제품명, pack size, 비고
    Cat. No. Product Component Note
    01GC610 STANDARD™ GlucoNavii® PRO Blood Glucose Monitoring System Meter, Test Strip (10EA) / Lancet(10EA) / Lancing Device
    01GS60 STANDARD™ GlucoNavii® PRO Blood Glucose Test Strip STANDARD™ GlucoNavii® PRO Test Strip (25EA x 2 bottle)
  • Download
    제품 기능 설명-Model,SD CHECK GOLD 2,STANDARD CodeFree,STANDARD CodeFree Plus(CodeFree Plus BT),SD CHECK GOLD 2,STANDARD Mentor(Mentor BT)
    Model STANDARD GlucoNavii Pro STANDARD GlucoNavii Pro BTSTANDARD CodeFree Plus BT01GS50STANDARD GlucoNavii NFCSTANDARD GlucoNavii GDHSTANDARD Mentor BTSTANDARD MentorSD CodeFreeSD CHECK GOLD 2 SD CHECK GOLD
    Meter STANDARD GlucoNavii Pro STANDARD GlucoNavii Pro BTSTANDARD CodeFree Plus BT01GS50STANDARD GlucoNavii NFCSTANDARD GlucoNavii GDHSTANDARD Mentor BTSTANDARD MentorSD CodeFreeSD CHECK GOLD 2 SD CHECK GOLD
    Enzyme GDH-FAD GDH-FADGODGODGDH-FADGDH-FADGODGODGODGODGOD
    Electrode GOLD GOLDGOLDGOLDGOLDGOLDGOLDGOLDGOLDGOLDGOLD
    Hematocrit 0~70% 0~70%20~60%20~60%0~70%0~70%20~60%20~60%20~60%20~60%20~60%
    Measurement Range 10~600 mg/dL 10~600 mg/dL10~600 mg/dL10~600 mg/dL10~600 mg/dL10~600 mg/dL10~600 mg/dL10~600 mg/dL10~600 mg/dL10~600 mg/dL10~600 mg/dL
    Test Time 5 seconds 5 seconds5 seconds5 seconds5 seconds5 seconds5 seconds5 seconds5 seconds5 seconds5 seconds
    Sample Volume 0.5µl 0.5µl0.9µl0.9µl0.5µl0.5µl0.3µl0.3µl0.9µl0.9µl0.9µl
    Sample Capillary,Venous Arteiral, Neonate Whole blood Capillary,Venous Arteiral, Neonate Whole bloodCapillary Whole bloodCapillary Whole bloodCapillary,Venous Arteiral, Neonate Whole bloodCapillary,Venous Arteiral, Neonate Whole bloodCapillary Whole bloodCapillary Whole bloodCapillary Whole bloodCapillary Whole bloodCapillary Whole blood
    Coding of strip No Coding No CodingNo CodingNo CodingNo CodingNo CodingNo CodingNo CodingNo CodingNo CodingCode Chip
    Memory 1,000 1,000100100300500500500500400400
    Operating Temperature 10~45℃  10~45℃ 10~45℃ 10~45℃ 10~45℃ 10~45℃ 10~45℃ 10~45℃ 10~45℃ 10~45℃ 10~45℃ 
    Color system Yes YesYesYesN/AN/AN/AN/AN/AN/AN/A
Top